Who this is for
- Home-decor importers
- Amazon lighting sellers
- Small hardware shops
What's inside
- 01 - Main Guide (78 pages, 15 chapters + 2 appendices): the whole stack, from classification to the file you keep.
- 02 - Compliance Checklist (printable): work it down before you ship.
- 03 - Document Templates: commercial invoice, packing list, supplier and forwarder emails.
- 04 - Landed-Cost Calculator (Excel): change the yellow cells, read the landed load.
- 05 - FAQ: the questions buyers actually ask, each answer points to a chapter.
- 06 - README: what each file is for and where to start.
HS code and duty
HS code: 8539.52.00 — LED light sources / lamps (example; verify HTS/TARIC). Fixtures/luminaires may instead be 9405.11 or 9405.21. The first 6 digits are the same worldwide. The last 4 digits change from country to country.
Duty and landed cost: Customs duty depends on the exact tariff classification and country of origin. Check the current U.S. HTSUS general or special rate and any additional Chapter 99 measures, including product-specific Section 301 duties where applicable. Rates and exclusions can change. State and local sales taxes are separate from customs import duty. Confirm the current classification and treatment with CBP before pricing or filing.
Compliance you may need
- Electrical safety and electromagnetic compatibility — UL or ETL listing, and FCC for electromagnetic compliance.
- California Proposition 65 and CPSIA limits for hazardous substances in electronics.
- US DOE energy-efficiency rules (including Level VI for external power supplies) for the market you are importing into.
- Dimmable / colour-temperature claims need supporting test data.
Common mistakes to avoid
- Confusing lamp (8539.52) vs luminaire/fixture (9405) classification and paying the wrong duty.
- Missing the energy-efficiency registration for your market — a common reason goods are held or refused at the border.
- Skipping hazardous-substance compliance and getting blocked at your market's border.
- Claiming 'dimmable' or a lumen output the product cannot meet — a labelling-compliance risk.
- Forgetting the EMC/EMI testing for driver circuitry, which your market requires.
What you'll learn
- Six Rates for One Light
- The Line That Decides: Lamp, Module, or Luminaire
- The Module Paradox: Why the Part Costs More Than the Whole
- Housing Material: 3.9%, 4.7%, 6.0%, 7.6%
- The Four-Layer Stack at a Glance
- Layer 1: MFN, and Why "Free" Is the Most Expensive Word Here
- Layer 2: Section 301, List 3, and Two Sources That Disagree
- Layer 3: Forced Labour at 12.5%, and the Vietnam Arithmetic
- Layer 4: MPF, HMF, and the Small-Shipment Trap
- Filing and Entry: Three Clocks, Four Lines, One Container
- The Lamp Rules: FTC Lighting Facts and $575 a Unit
- The DOE Rules: 45 Lumens per Watt and the 2028 Cliff
- FCC, Listing, and the Button Cell in the Remote
- Aluminium Extrusions, Prop 65, and the Scope You Did Not Read
- The Shipment-Day Checklist
Frequently asked questions
Do I need an energy label for a bulb sold in the US?
US rules on energy labelling are not the same as the EU's label requirement, and this is where a lot of advice online is wrong for American sellers. Before you order, ask your supplier for the certification file for the specific bulb and have your broker confirm what applies at the point of sale. Treat any label claim you cannot document as unusable.
Do LED bulbs fail more often than the old kind?
They do fail differently, and that matters for returns. Old bulbs failed by burning out; LED bulbs fail by flickering, going dim, or having a driver fail while the light still looks fine. Talk to your supplier about driver quality and the warranty you are going to offer, because a high return rate on a cheap product eats the margin quickly.
Is a bulb with a screw base different from one with a pin base?
For customs, both are lighting products and they sit together. For your customers, they are completely different products with different fittings, and buying the wrong base is the most common reason a lighting order sits unsold. Confirm the base type and the voltage before you order, not when you are packing the boxes.
What colour temperature should I import?
It is a commercial decision more than a compliance one, and it is decided per customer, not per shipment. Warm white sells in homes, cool white sells in offices and garages, and mixing them in one order makes the packaging work harder. Pick two temperatures and stick with them for your first run.
Does an LED light need certification?
Yes — electrical safety, hazardous-substance limits and energy-efficiency rules all apply. Ask your supplier which programmes they already hold a file for in your market.
What HS code do I use?
Usually 8539.52 (LED lamps). Confirm with your broker.
Is RoHS required?
In most markets, yes — it limits hazardous substances. Ask the factory for the declaration covering your market.
Do I need an energy label?
In many markets, yes — light sources can need an energy label before they can be sold. Check whether yours does, and get the label if it does.
Do I pay VAT when importing to the US?
No. The US has no federal VAT. You pay duty at the border, and your state may charge sales tax only when you sell — rates vary by state (example; check your state). The duty-free de minimis provision was suspended for most shipments from all countries effective 29 August 2025. Exceptions and entry-specific rules remain, so confirm current CBP treatment before shipping.
What is an ISF and do I need it?
For sea freight to the US you must file an Importer Security Filing (ISF, the 10+2) at least 24 hours before the ship loads. Miss it and Customs can fine you and hold the container. Air and courier shipments do not need ISF, which is one reason first-time importers choose air.